- Home
- Search Results
- Page 1 of 1
Search for: All records
-
Total Resources2
- Resource Type
-
0000000002000000
- More
- Availability
-
11
- Author / Contributor
- Filter by Author / Creator
-
-
ARMSTRONG, BRIDGET (1)
-
Ali, Muhammad (1)
-
CHANDRASHEKHAR, M_V S (1)
-
Jamil, Tariq (1)
-
Khan, Asif (1)
-
LANE, ABBI D (1)
-
MATOLAK, DAVID W (1)
-
MCANINCH, JONAS (1)
-
Mazumder, Abdullah_Al Mamun (1)
-
PARKER, HANNAH (1)
-
PATE, RUSSELL R (1)
-
RAHMAN, MAFRUDA (1)
-
Rahman, Mafruda (1)
-
SMITH, MICHAL T (1)
-
Simin, Grigory (1)
-
Stephenson, Kenneth (1)
-
WANG, YUAN (1)
-
WEAVER, R GLENN (1)
-
#Tyler Phillips, Kenneth E. (0)
-
#Willis, Ciara (0)
-
- Filter by Editor
-
-
& Spizer, S. M. (0)
-
& . Spizer, S. (0)
-
& Ahn, J. (0)
-
& Bateiha, S. (0)
-
& Bosch, N. (0)
-
& Brennan K. (0)
-
& Brennan, K. (0)
-
& Chen, B. (0)
-
& Chen, Bodong (0)
-
& Drown, S. (0)
-
& Ferretti, F. (0)
-
& Higgins, A. (0)
-
& J. Peters (0)
-
& Kali, Y. (0)
-
& Ruiz-Arias, P.M. (0)
-
& S. Spitzer (0)
-
& Sahin. I. (0)
-
& Spitzer, S. (0)
-
& Spitzer, S.M. (0)
-
(submitted - in Review for IEEE ICASSP-2024) (0)
-
-
Have feedback or suggestions for a way to improve these results?
!
Note: When clicking on a Digital Object Identifier (DOI) number, you will be taken to an external site maintained by the publisher.
Some full text articles may not yet be available without a charge during the embargo (administrative interval).
What is a DOI Number?
Some links on this page may take you to non-federal websites. Their policies may differ from this site.
-
Abstract In this paper we present a study of distribution polarization doped AlxGa1−xN layers and their use in quasi-vertical configuration pn-diodes which exhibited a high breakdown field of ∼8.5 MV cm−1and a large forward current density (∼23 kA cm−2). We also establish their potential use in UVC light emitters by studying the optical emission from a quantum well inserted at the distribution polarization doped pn-junction interface.more » « lessFree, publicly-accessible full text available May 1, 2026
-
ARMSTRONG, BRIDGET; WEAVER, R GLENN; MCANINCH, JONAS; SMITH, MICHAL T; PARKER, HANNAH; LANE, ABBI D; WANG, YUAN; PATE, RUSSELL R; RAHMAN, MAFRUDA; MATOLAK, DAVID W; et al (, Medicine & Science in Sports & Exercise)ABSTRACT IntroductionCurrent wearables that collect heart rate and acceleration were not designed for children and/or do not allow access to raw signals, making them fundamentally unverifiable. This study describes the creation and calibration of an open-source multichannel platform (PATCH) designed to measure heart rate and acceleration in children ages 3–8 yr. MethodsChildren (N = 63; mean age, 6.3 yr) participated in a 45-min protocol ranging in intensities from sedentary to vigorous activity. Actiheart-5 was used as a comparison measure. We calculated mean bias, mean absolute error (MAE) mean absolute percent error (MA%E), Pearson correlations, and Lin’s concordance correlation coefficient (CCC). ResultsMean bias between PATCH and Actiheart heart rate was 2.26 bpm, MAE was 6.67 bpm, and M%E was 5.99%. The correlation between PATCH and Actiheart heart rate was 0.89, and CCC was 0.88. For acceleration, mean bias was 1.16 mg and MAE was 12.24 mg. The correlation between PATCH and Actiheart was 0.96, and CCC was 0.95. ConclusionsThe PATCH demonstrated clinically acceptable accuracies to measure heart rate and acceleration compared with a research-grade device.more » « less
An official website of the United States government
